OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

With output power levels of 600W and 1000W, these popular power supplies can operate across a wide ambient temperature range of -40 (start up) to 74°C. Temperature controlled cooling fans ensure low acoustical noise – important for laboratory and measurement equipment. In addition to meeting the IEC 60950-1 safety standard, the SWS1000L has medical certification to IEC 60601-1.

SERIES TABLE

Model Voltage (V) Adjust Range (via Trim Pot) Max Curr. (A) Eff.(2)(typ)%
SWS600L-3 3.3V 2.64 – 3.96V 120 70 / 72
SWS1000L-3 3.3V 2.64 – 3.96V 200 74 / 76
SWS600L-5 5V 4 – 6V 120 75 / 77
SWS1000L-5 5V 4 – 6V 200 79 / 81
SWS600L-12 12V 9.6 – 14.4V 53 79 / 82
SWS1000L-12 12V 9.6 – 14.4V 88 82 / 84
SWS600L-15 15V 12 – 19.5V 43 79 / 82
SWS1000L-15 15V 12 – 19.5V 70 82 / 84
SWS600L-24 24V 19.2 – 28.8V 27 (31) 81 / 84
SWS1000L-24 24V 19.2 – 28.8V 44 (51) 84 / 86
SWS600L-36 36V 28.8 – 43.2V 18 82 / 84
SWS1000L-36 36V 28.8 – 43.2V 29 84 / 86
SWS600L-48 48V 38.4- 56V 13 (15) 82 / 84
SWS1000L-48 48V 38.4- 56V 22 (25) 84 / 86
SWS600L-60 60V 48 – 66V 10 82 / 84
SWS1000L-60 60V 48 – 66V 17 84 / 86
Note:   (2) 115 / 230Vac

SPECIFICATIONS TABLE

Input Voltage range 85 – 265VAC (47 – 63Hz) or 120 – 350VDC*
Inrush Current (115 / 230VAC) 20 / 40
Power Factor Meets EN61000-3-2 Class A
Temperature Coefficient <0.02%/°C
Overcurrent Protection >105%, Constant current style
Overvoltage Protection 125% -145%
Over temperature Protection Yes, cycle AC or Remote On/Off to reset
Hold Up Time (Typ) 20ms at 115/230VAC
Remote Sense Yes
Parallel Connection Yes
Remote On/Off (CNT) Yes
Voltage Programming Yes, 1-6V adjusts output from 20 – 120% of nominal
DC Good & Fan Fail Signal Yes, open collector output
Auxiliary Output 12V 0.1A
LED Indicator Green LED = On
Operating Temperature -40°C start up. -20°C to 74°C, derating linearly to 50% load above 50°C
Storage Temperature -40°C to +85°C
Humidity (non condensing) 20 – 90% RH operating, 10 – 95%RH non operating
Cooling Internal fan
Isolation Resistance >50MΩ at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) MIL-STD-810F 514.5 CAT. 4,10
Shock (in packaging) MIL-STD-810F 516.5 Procedure 1, V1
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety Agency Approvals UL/CSA/EN 60950-1, UL/CSA/IEC/EN 60601-1 & ANSI/AAMI ES60601-1,(1000W only), IEC61010-1 (600W only), EN50178, CE Mark
Conducted & Radiated EMI EN55011 / EN55022-B, FCC Class B