GEN750-1500 Laboratory Power Supplies: 750W -1500W

Brand: TDK LAMBDA

SKU: HPS-PS-LAB-GEN750-1500
This product is available globally.
  • High Power Density 750W / 1500W in 1U Rack
  • Wide range input: 85 ~ 264Vac, with Power Factor Correction
  • Output voltage up to 600V, current up to 200A
  • Labview & LabWindows drivers
  • Reliable Encoders for Voltage & Current adjustment

Product Range

SKU Variable Output Voltage Variable Output Current
GEN30-250-30V0-25A
GEN20-760-20V0-76A
GEN40-380-40V0-38A
GEN40-190-40V0-19A
GEN60-250-60V0-25A
GEN100-150-100V0-15A
GEN150-50-150V0-5A

Description

GEN750-1500

Laboratory Power Supplies: 750W -1500W

The Genesys™ Full-Rack (GEN-1U) series of DC Programmable Power Supplies provides high power density (up to 780W/1560W) with a complete set of user-friendly interfaces within a 1U full-rack profile. It offers Output voltages from 6V (@ 100A/200A) to 600V (@ 1.3A/2.6A) and a wide-range AC Input (85-265VAC, 47/63Hz) with Active Power-Factor Correction (0.99 @ rated load).

Constant-Current (CC) or Constant-Voltage (CV) Variable DC Power Supply

These units can operate in either Constant-Current (CC) or Constant-Voltage (CV) mode with a user-friendly front panel interface (continuous encoders for FINE and COARSE adjustment and four-digit LED Voltage and Current meters) and provide safety features such as Safe/Auto Re-Start, Last Setting Memory and built-in protective functions (OVP, UVL, Current FOLDback, OTP and AC Low-Line).

Remote Monitor & Control

Multiple remote programming/monitor/control methods are available including the built-in J1 Remote Analog and the RS232/RS485 Multi-Drop Remote Digital Interface (where up to 31 units may be controlled). Other Optional Remote Digital Interfaces (LAN, IEEE and USB) and Isolated Analog (5V/10V and 4-20mA) Interfaces are optional and factory installed (one per power supply). Instrument Software Drivers (NI LabView and NI LabWindows) are also available.

Additional information

WeightN/A
Dimensions436 × 422.8 × 44 mm
Variable Output Voltage

, , , , ,

Variable Output Current

, , , , ,

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN6-1000~6V0~100600
GEN6-2000~6V0~2001200
GEN8-900~8V0~90720
GEN8-1800~8V0~1801440
GEN12.5-600~12.5V0~60750
GEN12.5-1200~12.5V0~1201500
GEN20-380~20V0~38760
GEN20-760~20V0~761520
GEN30-250~30V0~25750
GEN30-500~30V0~501500
GEN40-190~40V0~19760
GEN40-380~40V0~381520
GEN50-300~50V0~301500
GEN60-12.50~60V0~12.5750
GEN60-250~60V0~251500
GEN80-9.50~80V0~9.5760
GEN80-190~80V0~191520
GEN100-7.50~100V0~7.5750
GEN100-150~100V0~151500
GEN150-50~150V0~5750
GEN150-100~150V0~101500
GEN300-2.50~300V0~2.5750
GEN300-50~300V0~51500
GEN600-1.30~600V0~1.3780
GEN600-2.60~600V0~2.61560

SPECIFICATIONS TABLE

 Input voltage/freq. (*1) 85~265Vac continuous, 47~63Hz, single phase
Power Factor0.99 @100/200Vac, rated output power.
EN61000-3-2,3 compliance Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power.
Input current 100/200Vac750W :10.5A / 5A, 1500W :21A / 11A
Inrush current 100/200Vac750W :Less than 25A, 1500 W :Less than 50A
Hold-up timeMore than 20mS, 100Vac, at 100% load
Parallel OperationUp to 4 units in master/slave mode with single wire current balance connection
Series OperationUp to 2 units. with external diodes. 600V Max to Chassis ground
Operating temp0~50°C, 100% load
Operating humidity30~90% RH (non-condensing)
 VibrationMIL-810E, method 514.4, test cond. I-3.3.1. The EUT is fixed to the vibrating surface.
ShockLess than 20G, half sine, 11mSec. Unit is unpacked.