The Genesys 1U Full-Rack (GEN-1U) series of 2400W DC Programmable Power Supplies provides high power density (up to 2400W) with a complete set of user-friendly interfaces within a 1U (1.75″) profile.
This series offers Output voltages from 8V (@ 300A) to 600V (@ 4.0A) in both Single-phase 230VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.99 @ rated load) and Three-phase 208VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load) and two Auxiliary Outputs (15.0V @ 0.2A and 5.0V @ 0.2A) for use with Remote Analog Control/Status.
Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.
Model | Output Voltage (VDC) | Output Current ( A ) | Output Power ( W ) |
GEN 8-300 | 0~8V | 0~300 | 2400 |
GEN 10-240 | 0~10V | 0~240 | 2400 |
GEN 16-150 | 0~16V | 0~150 | 2400 |
GEN 20-120 | 0~20V | 0~120 | 2400 |
GEN 30-80 | 0~30V | 0~80 | 2400 |
GEN 40-60 | 0~40V | 0~60 | 2400 |
GEN 60-40 | 0~60V | 0~40 | 2400 |
GEN 80-30 | 0~80V | 0~30 | 2400 |
GEN 100-24 | 0~100V | 0~24 | 2400 |
GEN 150-16 | 0~150V | 0~16 | 2400 |
GEN 300-8 | 0~300V | 0~8 | 2400 |
GEN 600-4 | 0~600V | 0~4 | 2400 |
Input Voltage / Frequency (range) | Single Phase,230V models: 170~265Vac, 47~63Hz,3-Phase, 208V models: 170~265Vac, 47~63Hz |
Inrush Current | Single-Phase and 3-Phase 208V models: Less than 50A |
Power Factor | Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208Vac, rated output power. |
Parallel Operation | Up to 4 identical units in master/slave mode |
Series Operation | Up to 2 identical units. with external diodes. 600V Max to Chassis ground |
Operating temp | 0~50°C, 100% load. |
Storage temp | -20~85°C |
Operating humidity | 20~90% RH (non-condensing). |
Storage humidity | 10~95% RH (non-condensing). |
Vibration | MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. |
Shock | Less than 20G , half sine, 11mSec. Unit is unpacked. |
Altitude | Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. |
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m). | |
RoHS Compliance | Complies with the requirements of RoHS directive. |