OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

The EN54 Series is a new generation / smart Power Supply that is designed to provide battery backed-up power in the event of either the PSU or the battery being disconnected or short circuited.

When the AC supply fails, the battery will automatically be connected and will provide power until the ac supply is restored.. If the battery has reached its disconnect voltage, it will automatically be disconnected to prevent deep discharge damage.

Designed for powering critical loads with battery back-up, in a wide range of Industrial applications and in particular Security installations and Access Control, with separate Load and Battery Charging circuits.

A wide range of Signals, Led’s and Alarms, all aimed at a providing the optimum solution for powering critical DC Loads.

An isolated Common Fault relay has been provided which will operate if any fault is found (This is a fail-safe signal so will signal a fault even if no power sources are on/connected.

SPECIFICATIONS TABLE

INPUT
Input voltage 200 – 240 Vac +/-10%
Frequency Range 50-60Hz
Temperature Range 0 – 50ºC ambient (Convection cooled, cased)
Input fuse T2H 250V TR5
Input Current 1.6Arms (200Vacin, full load)
Hold-up Time 30mS (230Vacin, full load, no battery connected)
Power Factor 0.45 (230Vacin, Full load)
No Load Power 1.5W (230Vacin)
Start-up Less than 1.5 seconds
OUTPUT
Output Voltage 27.6V (factory set for operation with thermistor)
Output Current 4A
Power limit 115% +/-10%
80-85% Typ.@ 230Vacin, Full load
OVP 105-125% (latching and non dissipative) recycle input to restart
Short Circuit protection Hiccup mode
Signals Mains Fail, Battery O/C, Charger Loss, Battery Low- LED’s & open collector – 100mA sink, Status LED Green = Flashing = OK
Common Fault (Volt free) relay
2x Customer options – open collector – 30mA sink HiZ indication =0.6J
Battery Powerfail signal = 100mS
Current limit Primary side power limit
Thermal protection Primary side thermal protection (non-latching)
Load regulation +/- 0.75%
Line regulation +/- 0.5%
Noise & ripple 0.5% (230Vacin, Full load, BW = DC – 10MHz)
BATTERY
Charger Current limited @ 1 A
Temp compensation Connector provided for user to add 100KΩ  thermistor (β=4400) Suitable for standby use
Deep discharge protection 21V +/-0.25V