OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

The BCH800-1K series battery charger is a rugged, industrial-grade product, using field- proven design suitable for use in DC battery back-up applications.It is a mature product providing excellent reliability and performance and delivering up to 1000 watts of output power with convection/conduction cooling. – NO Fans

The two alarms provide external monitoring of Power Fail / Charger Fail and Battery Low via voltage free contacts.

The chassis-mount design feature allows for easy mounting.

Additional ruggedizing and conformal coating are available for applications requiring higher immunity to shock, vibration, humidity, moisture, dust and insects.

Options

  • TBC Temperature Battery Compensation Charging.
  • TIM Automatic Battery Testing.
  • Boost A variety of boost options.

SERIES TABLE

Model Output  Nom Float V Current   Power
BCH800-28FT 24 V 27.6 V 29A 800W
BCH800-55FT 48 V 55.2 V 14A 800W
BCH1K-110FT 96 V 108 V 8.0A 990W
BCH1K-110FT 108 V 124 V 8.0A 990W
110V model adjustable for use on 96V or 108V nominal battery systems.

SPECIFICATIONS TABLE

Input Voltage 230VAC ( 190 ~ 264 )
Input Frequency  47 ~ 63Hz
Input Current 9.5A
Input Protection Inrush current limiting
Transient protection / Varistors
Internal safety fuse
Output Voltage Refer to table
Overload
Protection
Constant current limiting with short circuit
protection.Battery must be externally fused.
Efficiency Typically 80%
Overvoltage
Protection
Constant current limiting with short circuit
protection.
Battery must be externally fused
Parallel Operation Yes.
Switching Freq. Typically 55KHz
Operating Temp. 0ºC to +50ºC at full load.
Derate 2.5% per ºC to +70ºC
Cooling Conduction / convection cooled via base plate
Humidity 5-95% non-condensing
Ripple & Noise Typically <1% of output voltage
Insolation Input-Output: 3Kvac,
Input-Frame Ground: 2kVAC
Output-Frame Ground: 500VAC.
EMC EN55022 Class A
Immunity EN 61000-4-2 (ESD)
EN 61000-4-3 (RF Immunity)
EN 61000-4-4 (Fast Transients)
EN 61000-4-6 (Conducted Imm.)
MTBF >150,000hrs @ 45ºC
Dimensions 351 x 210 x 66mm