OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

The BCH300 & BCH500 series battery charger is a rugged, industrial-grade product, using field- proven design suitable for use in DC battery back-up applications. It is a mature product providing excellent reliability and performance and delivering 300 / 500 watts of output power with convection/conduction cooling. – NO Fans.

The two alarms provide external monitoring of Power Fail / Charger Fail and Battery Low via voltage free contacts.

The chassis-mount design feature allows for easy mounting.

Additional ruggedizing and conformal coating are available for applications requiring higher immunity to shock, vibration, humidity, moisture, dust and insects

Options

  • TBC Temperature Battery Compensation Charging.
  • TIM Automatic Battery Testing.
  • Boost A variety of boost options.
  • IEC AC input via IEC socket & power cord.
  • Rack Mount 19in Rack Mount options.

SERIES TABLE

 

Model Output  Nom Float V Current   Power
RM-BCH300-14FT 12 V 13.8 V 20A 300W
RM-BCH300-28FT 24 V 27.6 V 11A 300W
RM-BCH300-55FT 48 V 55.2 V 5.5A 300W
RM-BCH300-110FT 96 V 108 V 2.5A 300W
RM-BCH300-110FT 108 V 124 V 2.5A 300W
RM-BCH500-28FT 24 V 27.6 V 18A 500W
RM-BCH500-55FT 48 V 55.2 V 9A 500W
RM-BCH500-110FT 96 V 108 V 4A 500W
RM-BCH500-110FT 108 V 124 V 4A 500W
For Digital Meters, change part no to: RMM-BCH300-xxx RMM-BCH500-xxx
110V model adjustable for use on 96V or 108V nominal battery systems

SPECIFICATIONS TABLE

Input Voltage 230VAC ( 190 ~ 264 )
Input Frequency  47 ~ 63Hz
Input Current BCH300 @ 2.8A
BCH500 @ 4.7A
Input Protection Inrush current limiting
Transient protection / Varistors
Internal safety fuse
Output Voltage Refer to table
Overload
Protection
Constant current limiting with short circuit
protection.Battery must be externally fused.
Efficiency Typically 80%
Overvoltage
Protection
Yes. Recycle mains input to re-set
Parallel Operation Yes. Recycle mains input to re-set
Current Limit Primary side power limited
Operating Temp. 0ºC to +50ºC at full load.
Derate 2.5% per ºC to +70ºC.
Cooling Conduction / convection cooled via base plate
Humidity 5-95% non-condensing
Ripple & Noise Typically <1% of output voltage
Insolation Input-Output: 3Kvac,
Input-Frame Ground: 2kVAC
Output-Frame Ground: 500VAC.
EMC EN55022 Class A
Immunity EN 61000-4-2 (ESD)
EN 61000-4-3 (RF Immunity)
EN 61000-4-4 (Fast Transients)
EN 61000-4-6 (Conducted Imm.)
MTBF >150,000hrs @ 45ºC
Dimensions 2U x 19in x 420mm Rack Mount