OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

The RWY 182 Series fully encapsulated, dual output, railway quality DC/DC converter uses field?proven topology to generate 200W output power. It employs forward topology on one output and push pull topology on the other.ÿÿBoth outputs are individually regulated and current limited.This is a mature product with a track?record in numerous applications.The unit is entirely potted with a thermally conductive MIL?grade silicon rubber compound to ensure immunity to shock, vibration and humidity.ÿÿIt is conduction cooled via a base plate to a heat?sinking surface.Low component count, large design headroom, and the use of components with established reliability result in a high MTBF. The unit meets the requirements of EN50155 for Electronic equipment used on rolling stock. The unit is also suitable for transportation, mining, oilrigs, military and other harsh environments.ÿ

RWY182 Series Datasheet

SERIES TABLE

Model Output ( V1) Output ( V2) Power (W)
RWY182 Any voltage
5V – 72V limited to
8A / 100W
Any voltage
5V – 72V limited to
8A / 100W
200W

SPECIFICATIONS TABLE

Operating input voltage range 24VDC   ( 14.4 ~ 34 )
36VDC   ( 22 ~ 51 )
48VDC   ( 20 ~ 67)
72VDC   ( 43 ~ 101)
96VDC   ( 58 ~ 135)
110VDC   ( 66 ~ 154)
Input Protection Reverse polarity protection.Inrush current limiting Lower voltage than specified will not damage unit
Output Voltage See  table
Regulation ±1% Line / Load combined
Operating Temp:  -40ºC to +70ºC cold plate temperature
Efficiency Model dependent , typically 80-90%
Dynamic Response Max ±5% diviation for 10% – 50% load step wuth 1msec recovery
MTBF >160,000 hrs