OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

E-one is a compact inverter providing a pure sine wave AC supply. In conjunction with a DC Power system, it provides an excellent AC backup solution. It uses the latest inverter technology, providing superior energy efficiency in a compact size.e-one inverter has DC input on front terminal, AC output socket protected with 10 A fuse.e-one can be easily rack mounted, wall, or desk mounted.

Best in-class solution?  

With dimensions of 1U x 342 mm x 221 mm, this very small inverter occupies just 3,300 cm³.

We also guarantee a maximum ripple voltage of 0.01%, or 0.048V on the DC source. In practical terms, this means almost no disturbances reach your DC load or batteries; a great benefit as disturbances considerably reduce battery life.

To minimize your maintenance costs, E-one has incorporated a variable fan speed for cooling. The fan’s speed changes, or it switches off entirely, according to need. This reduces fouling and other maintenance problems.

Finally, regarding reliability, the e-one inverter is based on our Y-one inverter which has the lowest conceivable failure rate: 0%.

For which application?

e-one is the ideal solution for powering and securing any AC equipment; maintenance, supervision, cooling, security, access or small cells for 5G. It was designed for base stations (BTS, NodeB and eNodeB) for mobile telecommunicationfixed telecommunication and railway communication (GSMR).

SPECIFICATIONS TABLE

POWER REG 1000 VA / 800W
EMC (immunity) EN 61000-4-2 up to 6
EMC (emission) (class) EN 55022 (A)
Safety IEC 60950-1
Cooling / Isolation Forced / Doubled
MTBF 200 000 hrs
Efficiency DC/AC at 54 VDC 0.9
Dielectric strength DC/AC 4300 Vdc
RoHS Compliant
Vibration GR63 office vibration 0 to 100 hz-0.1 g / transport vibration 5-100 Hz 0.5 g 100 to 500 hz-1.5 g / Drop test
Operating conditions Self adaptive to wide operating conditions and comprehensive table of troubleshooting codes
Altitude above sea without de-rating < 1500 m / derating > 1500 m – 0.8 % per 100 m
Ambient / storage temperature / relative humidity -20 to 50 ° C / -40 to 70 ° C / 95 %, non-condensing
Material (casing) Coated steel
AC OUTPUT POWER
Nominal Output power (VA) / (W) 1000 VA / 800 W
Short time overload capacity 150 % (15 seconds) within T° range
Admissible load power factor 0 lagging to 0 leading
DC INPUT SPECIFICATIONS
Nominal voltage (DC) 48 V
Voltage range (DC) 40 – 60 V
Nominal current at 800 W / 48 VDC 19 A
Maximum input current (for 15 second) / voltage ripple 28 A / 2 mV psopho @ 48 V – 80% LOAD
AC OUTPUT SPECIFICATIONS
Nominal voltage (AC*) 230 V
Frequency / frequency accuracy 50 or 60 Hz / ± 0.01 %
Total harmonic distortion (resistive load) < 1.5 %
Load impact recovery time 0.4 ms
Turn on delay 20 s
Nominal current. Protected against reverse current 4.4 A at 230 VAC
Crest factor at nominal power 3 : 1
With short circuit management and protection 3 : 1
SIGNALING & SUPERVISION
Display Front LED
Alarms output / supervision Dry contact on the front
Remote on / off On the front