OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

The ICT Distribution Series 2 DC Distribution Panels are designed to be used in 12, 24 or 48VDC applications. All models feature 12 fused output positions. For +12/24VDC models, nine outputs are ATO/ATC type fuses rated at up to 25 amps each, and three are JCASE type fuses rated at up to 40A each. For +/- 48VDC models, 12 outputs are GMT type fuses rated at up to 15 amps each. Fuses and LED indicators are located on the front, enabling easy monitoring and replacement.An integrated security protected Ethernet communications port (select models) allows the panel to be monitored from a remote site using an industry standard web browser. HTTPS and SNMP V1/V2c protocols are supported. System current, system voltage, individual output currents and fuse status can be monitored, and alarms can be sent to multiple email accounts.

DC outputs can be turned on and off remotely (select models), allowing connected loads to be power-cycled using the Ethernet connection. Automatic load-shedding can be defined to protect critical loads. A network watchdog feature will ping up to two I.P. addresses and power-cycle loads such as routers which may need rebooting to restore communications with the site.

SERIES TABLE

MODEL  DESCRIPTION  NOMINAL APPLICATION VOLTAGE  PANEL CURENT RATING (CONTINUOUS) 
ICT180S-12I Intelligent Distribution Panel 12 and 24VDC 150A
ICT180S-12B Broadband Distribution Panel – 48VDC 150A
ICT180S-12IRC Intelligent Distribution Panel with remote power control 12 and 24VDC 150A
ICT180S-12BRC Broadband Distribution Panel with remote power control – 48VDC 150A
ICT180S-12BRCP Broadband Distribution Panel with remote power control +48VDC 150A

SPECIFICATIONS TABLE

Mechanical
Form Factor 1RU – 19 Inch rack mount with handles
Dimensions (inches) L x W x H 9.29 x 19.0 x 1.72
Weight (lbs/kg) 7.0 lbs / 3.2 kg
Fuse Position Front Panel
LED Alarm Indicators Front Panel
LCD Digital Display Front Panel
Rear Panel Connectors
Power and Communications DC input stud connectors, DC output terminal blocks, Form C alarm contacts, grounding stud, RJ-45 Ethernet
Site Monitoring Five external dry alarm contacts. Monitors external contact closure, configurable for NO or NC logic, applied voltage 3.3V, 0.4mA for contact closure detection
Environment
Operating Temperature Range -30C to +60C
Communications and Control
Ethernet TCP/IP built-in web server and graphical user interface, 10/100BASE-T, IEEE 802.3 compatible
Supported Protocols IPv4, HTTP, HTTPS, SMTP, DNS, TCP, UDP, ICMP, DHCP, ARP, SNMP v1/v2c
SNMP Ports UDP Port 161, SNMP Traps: UDP Port 162
Firmware Upgrades Upgradeable over Ethernet
Security Password protected, SSL encryption
12 Channel Output Monitoring Current draw measured and reported for each output, definable under and over current alarms
Email and SMS Alerts Multiple email or text accounts, adjustable intervals
Data Logging Up to 30 days at 1 minute sampling rate, csv file download, major event logging
Network Watchdog Autonomously ping up to two I.P. addresses and power-cycle output if no response, definable settings
Remote Alarms Form C alarm contacts (C/NO/NC)