OUR OFFICE LOCATIONS

blog-placeholder

Helios Power Solutions
New Zealand

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

1 Heremai Street,
Henderson, Auckland,
New Zealand, 0612

Contact Info

Email: sales@heliosps.co.nz
Phone: +64 9 835 0700

blog-placeholder

Helios Power Solutions
Australia

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

Unit 6, 2-8 South St,
Rydalmere,Sydney,
NSW, Australia, 2116

Contact Info

Email: sales@heliosps.com.au
Phone: +61 2 7200 9200

blog-placeholder

Helios Power Solutions
Asia & Middle East

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor sit amet, consectetur adipiscing. Ut enim ad minim veniam, quis nostrud. Lorem ipsum dolor.

Office Address

168 Robinson Road,
#12-01 Capital Tower
Singapore 048545

Contact Info

Email: sales@heliosps.asia
Phone: +65 6871 4140

ADC5000 AC/DC Switch Mode Power Supplies

ADC 5000 is a series of compact and stable power supplies suitable for all types of industrial application. Suitable for battery chargers with very low ripple, built-in series diode and temperature regulated output voltage. LED indication for supply output voltage. Stable, mechanical construction, high efficiency, and convection cooling ensure long service life. Available with 12, 24, and 48 VDC output voltage.

  • Input voltage 230/115 VAC
  • Output voltages 12, 24, 36 or 48 VDC
  • Statistical MTBF >3 000 000 hours
  • Built-in output series diode
  • Temperature compensated battery charging
  • Wide output adjustment range
  • Efficiency 82…90%
  • Operating temperature –40 °C…+70 °C (see derating)
  • EMC EN55022B (telecom)

Specifications Table

SPECIFICATION 60W 125W 250W
12V 24V 36V 48V 12V 24V 48V 12V 24V 48V
INPUT
Input voltage 90…264 VAC / 85…200 VDC
(DC input is not UL60950-1 approved)
94…132 VAC or 184…264 VAC selectable by switch
Frequency 45…65Hz
Input current, 100% load, 230VAC
Input current, 100% load, 115VAC
0.8A
1.4A
1.4A
2.4A
ADC5xxx 2.5A, ADC5xxxP 1.9A
ADC5xxx 4.5A
Efficiency, typical (230 VAC, 100% load) >82% >83% >83% >84% >85% >88% >89% >85% >89% >90%
Isolation Input / ground 1500 VAC RMS 50Hz, 1min, Input / output 3000 VAC RMS 50Hz, 1min.Output / ground 500 VDC
Inrush current (25Cº), 230VAC
Inrush current (25Cº), 115VAC
<25A <5ms
<12A <10ms
<45A <5ms
<22A <10ms
<35A <5ms
<17A <10ms
Input fuse T3.15A, high breaking T4A, high breaking T6.3A, High breaking
Overvoltage transient protection VDR 275VAC 72J
OUTPUT
Output voltage, PSU models (50% load) Output voltage, rectifiers (50% load)
Output adjustment (typical)
12V
13.7V
10,5…15V
24V
27.4V
21…29V
36V
41.1V
33…44V
48V
54.8V
45…58V
12V
13.7V
9…15V
24V
27.4V
21…29V
48V
54.8V
45…58V
12V
13.7V
9…15V
24V
27.4V
21…29V
48V
54.8V
45…58V
Ripple voltage  (20Hz…300kHz,  25°C) <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms <15mVrms
Load regulation (without series diode) <1.0 % <0.5 % <0.5 % <0.5 % <1.0 % <0.5 % <0.5 % <1.0 % <0.5 % <0.5 %
Line regulation < 0.15 %, Uinmin…Uinmax
Temperature coefficient < 0.02 % / °C
Current limit (refer curve page 5) <8A <4A <3A <2A <11A <6A <3A <22/20A <11A <6A
Short circuit current (refer curve page 5) <14A <9A <8A <6A <16A <10A <6A <27A <14A <9A
Hold-up time (230V, 100% load) >50ms >50ms 50ms 50ms >20ms >20ms >20ms >20ms >20ms >20ms
ALARMS AND INDICATIONS
Output OK Green LED
Power Fail relay alarm Relay contacts Normally Open and Closed, Activated at AC fail and module fail cases
Relay contact rating: 24VDC/0.3A or 30VAC/0.5A
Undervoltage alarm threshold level 10.2V ±0.5 V   20V ±1V 28V ±1V 41V ±2V 8.3V ±0.5V 19V ±1V 39V ±2V 8.3V ±0.5V 19V ±1V 39V ±2V
Output overvoltage protection level 16V 30,5V 46V 61V 16V 31V 60V 16V 31V 60V
Series diode at output Output can be equipped with internal series diode, diode in 125/250W models, FET circuit in 60W models
Optional Shutdown Shutdown by external voltage 4…15VDC to RC pin
Optional battery test control Float charge voltage can be reduced by external 4…15VDC control to allow battery test by using external measurement circuit
Temperature compensation (rectifiers) By external NTC resistor 2.2 kohm, included in rectifier models delivery
MECHANICAL
Dimensions (w x h x d) 51 x 121 x 81 mm 66 x 148 x 113 mm 75 x 173 x 122 mm
Can be installed both horizontally and vertically (3 different installation choices)
Weight 360 g 840 g ADC5xxx 1.3kg, ADC5xxxP 1.5kg
Enclosure Steel / aluminium enclosure IP20
Connectors Removable 2.5 mm² screw terminals
ENVIRONMENTAL
Storage temperature
Operation temperature
-40°C…+85°C
-40°C…+70°C, full power up to +55C (expect 250W/12VDC models), See derating curves
Cooling Natural convection
Humidity
85% RH
95% RH coated PCBs in R-versions
Do not energize while condensation is present.
Shock and vibration ETS 300 019-2-4, class 4M5,
Vibration, sin, IEC60068-2-6, 2gn 9-200m/s2, Vibration, broad-band random, IEC60068-2-64
STANDARDS, APPROVALS
Safety standards EN 60950-1 class 1 including CB certificate and U.S. deviations according to UL60950-1 class 1 UL508 industrial control equipment (not all models, refer page 2)
EMC emissions EN61000-6-3 EN 55022 class B conducted and radiated emissions
EN61000-3-2 harmonics (not 250W models without P in type number) EN61000-3-3 Flickering
EMC Immunity EN61000-6-2 EN 61000-4-2 Electrostatic Discharge EN 61000-4-3 Radiated Immunity
EN 61000-4-4 Fast Transients EN 61000-4-5 Surge
EN 61000-4-6 Conducted Immunity
EN 61000-4-8 Power frequency magnetic field immunity EN 61000-4-11 Voltage dips and interruptions, immunity
Approvals CE-marking, CB certificate EN60950-1/UL60950-1, UL508 cUL listing (not all models, refer page 2)

POWER SUPPLY MODELS DIN/WALL

POWER SUPPLY MODELS DIN/WALL
Type
*) xy
see below
Available
xy  selection codes (others on request)
Input Voltage Output Voltage Output Voltage Adjustment Output Current Power Mechanical Dimensions (W x H x D) Note
see below
ADC56xy xy = 23, 33 90…264 VAC 12 VDC 10.5…15 VDC 5 A 60 W 51 x 121 x 81 mm
ADC50xy On request 230/115 VAC 12 VDC 9…15 VDC 10 A 120 W 66 x 148 x 113 mm
ADC53xy xy = 23 230/115 VAC 12 VDC 9…15 VDC 20/18 A 240 W 75 x 173 x 122 mm **)  ***)
ADC53xyP On request 230/115 VAC 12 VDC 9…15 VDC 20/18 A 240 W 75 x 173 x 122 mm ***)
ADC57xy xy = 21, 23 90…264 VAC 24 VDC 21…29 VDC 2.5 A 60 W 51 x 121 x 81 mm
ADC51xy xy = 21, 23, 31 230/115 VAC 24 VDC 21…29 VDC 5 A 120 W 66 x 148 x 113 mm
ADC54xy xy = 21, 23 230/115 VAC 24 VDC 21…29 VDC 10 A 240 W 75 x 173 x 122 mm **)
ADC54xyP On request 230/115 VAC 24 VDC 21…29 VDC 10 A 240 W 75 x 173 x 122 mm
ADC59xy On request 90…264 VAC 36 VDC 33…44 VDC 1.7 A 60 W 51 x 121 x 81 mm ***)
ADC58xy On request 90…264 VAC 48 VDC 45…58 VDC 1.25 A 60 W 51 x 121 x 81 mm
ADC52xy On request 230/115 VAC 48 VDC 45…58 VDC 2.5 A 120 W 66 x 148 x 113 mm
ADC55xy xy = 23 230/115 VAC 48 VDC 45…58 VDC 5 A 240 W 75 x 173 x 122 mm **)
ADC55xyP On request 230/115 VAC 48 VDC 45…58 VDC 5 A 240 W 75 x 173 x 122 mm
8750230A Finger protected power cord for ADC5000-series models

RECTIFIER MODELS DIN/WALL

RECTIFIER MODELS DIN/WALL, FLOAT OUTPUT VOLTAGE LEVEL (See Application (A) page 1)
Type
*) xy
see below
Available
xy  selection codes (others on request)
Input Voltage Output Voltage Output Voltage Adjustment Output Current Power Mechanical Dimensions (W x H x D) Note
see below
ADC56xy xy = 81, 83 90…264 VAC 13.7 VDC 10.5…15 VDC 4.4 A 60 W 51 x 121 x 81 mm
ADC50xy xy = 81, 83 230/115 VAC 13.7 VDC 9…15 VDC 10 A 137 W 66 x 148 x 113 mm
ADC53xy xy = 83 230/115 VAC 13.7 VDC 9…15 VDC 20/18 A 274 W 75 x 173 x 122 mm **)  ***)
ADC53xyP On request 230/115 VAC 13.7 VDC 9…15 VDC 20/18 A 274 W 75 x 173 x 122 mm ***)
ADC57xy xy = 83 90…264 VAC 27.4 VDC 21…29 VDC 2.2 A 60 W 51 x 121 x 81 mm
ADC51xy xy = 81, 83 230/115 VAC 27.4 VDC 21…29 VDC 5 A 137 W 66 x 148 x 113 mm
ADC54xy xy = 81, 83 230/115 VAC 27.4 VDC 21…29 VDC 10 A 274 W 75 x 173 x 122 mm **)
ADC54xyP xy = 85 230/115 VAC 27.4 VDC 21…29 VDC 10 A 274 W 75 x 173 x 122 mm
ADC59xy On request 90…264 VAC 41.4 VDC 33…44 VDC 1.5 A 60 W 51 x 121 x 81 mm ***)
ADC58xy On request 90…264 VAC 54.8 VDC 45…58 VDC 1.1 A 60 W 51 x 121 x 81 mm
ADC52xy On request 230/115 VAC 54.8 VDC 45…58 VDC 2.5 A 137 W 66 x 148 x 113 mm
ADC55xy xy = 83, 93 230/115 VAC 54.8 VDC 45…58 VDC 5 A 274 W 75 x 173 x 122 mm **)
ADC55xyP On request 230/115 VAC 54.8 VDC 45…58 VDC 5 A 274 W 75 x 173 x 122 mm
8750230A Finger protected power cord for ADC5000-series models

*) y selection code:
Standard features:
All models 1 = Module fail alarm relay + Output over voltage protection (OVP),
3 = Output series diode + Module fail alarm relay + Output OVP
Optional features:
125/250W models 0 = Alarm relay + Shut down, 2 = Output series diode + Alarm relay + Shut down, (No OVP)
125/250W rectifiers 4 = Output remote control for battery test + alarm relay + Output OVP,
5 = Output remote control for battery test + alarm relay + Output OVP + Output series diode
Letter P models include passive power factor correction coil
**) Marked model does not comply with EN61000-3-2 harmonics standard.
These can be used in following applications: the unit is not directly connected to the public mains network, or
if the unit is installed in a professional equipment with a total rated power greater than 1kW, or if the input
current of the equipment is greater than 16A per phase
***) Marked models are not UL508 listed, 12V/ 20A model max current with series diode 18A

Optional: ADC5000 R-versions for rugged environment, Type number for example ADC5183R