Dual Output Voltage DC Power System for wireless communication networks

New Dual Output DC Power System for Wireless Communications Networks

48V And 24V DC Power System With Integrated 12V Or 24V DC Converter

Managing your backup system and critical loads with two different voltage levels is now possible with the new ICT Hybrid Ultra and ICT Hybrid Power Series. The dual output voltage configuration brings more flexibility while maintaining a high level of reliability with the standard battery management features and ethernet enabled monitoring capabilities. The new series are ideal for restricted space applications where the primary DC voltage is positive or negative 48V or 24V DC, and auxiliary voltage of 12V or 24V DC is required to power certain devices at the site.

ICT Hybrid Ultra Series

  • Up to 7500W output Power
  • 700W/1500W AC-DC Power modules – 48V or 24V DC output
  • 700W DC-DC Converter Module – 12 VDC output
  • Dual 100 amp battery breakers with battery management module
  • 4 or 8 fully managed load outputs
  • Digital and analog inputs for temperature and site sensors
  • Full range of certifications including CSA/UL, FCC Class B, CE, ROHS

ICT Hybrid Power Series

  • Up to 3000W output Power
  • 700W/1500W AC-DC Power modules – 48V or 24V DC output
  • 700W DC-DC Converter Module – 12 VDC output
  • Dual 100 amp battery breakers with battery management module
  • Digital and analog inputs for temperature and site sensors
  • Full range of certifications including CSA/UL, FCC Class B, CE, ROHS

Applications

Two-way Communications Networks

Trunked Radios Systems

Backhaul

DAS

SCADA

Security & Surveillance

Main Features of Modules

Integrated Intelligent Control Module – ICM Controller
  • TCP/IP remote Ethernet communications for monitoring and control
  • Embedded web server for plug and play set up
  • HTTP/HTTPS, SMTP, SNMPv1/v2c/v3 protocols supported
  • AC input voltage, DC output voltage, system current reporting (local and Ethernet)
  • Four site monitoring sensor inputs with alarm reporting
  • Local and remote output voltage and current limit adjustment
  • Up to 30 days logging at 1 minute sampling rate, csv file download, major event logging
Integrated Load Distribution Module (just for Hybrid Ultra Series)
  • Display current reading of each of four load outputs
  • Remote on/off control of individual outputs or entire load bus over Ethernet
  • User definable alarm level indications (sent via Form C and Ethernet)
  • User-definable load disconnect and reconnect levels
  • Definable automatic load shedding
  • Auto-ping automatic power cycling of specified load outputs
  • Power-up delay sequencing
Battery Management Module
  • Temperature-compensated charging
  • Display of battery voltage status
  • Battery current, state of charge, run time remaining reporting
  • Adjust LVD settings
  • Configure advanced battery management features such as
    • Boost charge parameters
    • Max charge current
    • Battery capacity
    • Battery test timer
    • Battery discharge test cut-off voltage.
This features are available with Lead Acid batteries. The modular series is compatible with Lithium-ion batteries but battery monitoring and reporting is done by the battery itself. (read Using DC Power Supplies and Battery Chargers with Lithium-ion batteries for more info)

Contact Us For Technical Assistance

For technical support about our off the shelf products and customised power conversion solutions, get in touch today.

Related posts

AMP-Kxxx , CSB & CAB Custom DC & AC Power Conversion Solutions

More than 40 years of experience getting to know the needs of our customers allows us to understand power problems better than other providers, and to quickly design/deliver solutions specifically tailored to solve your engineering challenges. Our product range includes over 500 standard products and more than 2000 custom-made designs, including Inverter Charger Systems, Battery Charger for Industrial Applications, Battery racks, and customised form factor designs to easily fit into existing installations.

Comms Connect 2023DC Power Supplies for critical communications Helios Power Solutions

Largest Gathering of Critical Comms Leaders in the Southern Hemisphere

At Helios, we are pleased to see Comms Connect return to Melbourne on Wednesday 18th and Thursday 19th October.

Our engineers Julian Clark, Ace Hassan from Australia and Jason Jost from New Zealand are so looking forward to catching up with you and assisting your power conversion and back up challenges.

Protocol Testing DNP3 Outstation Server

Distributed Network Protocol 3 (DNP3) is a non-proprietary protocol that enables reliable, efficient, and secure communication between remote master stations and outstations in industrial automation systems. It is widely used in the water, transport, Oil & Gas and electricity industries in Australia and New Zealand due to its need for timestamping, security, and openness.